- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000001000000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Herbst, Amanda (1)
-
Marrec, Pierre (1)
-
Menden-Deuer, Susanne (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
& Attari, S. Z. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
The continuous underway fluorescence, induced by in vivo chlorophyll-a (Chl-a), of surface waters of the Northeast U.S. shelf is compared to discrete Chl-a samples for post-calibration, collected ship-board as part of the Northeast U.S. Shelf Long-Term Ecological Research (NES LTER). Chl-a values derived from the manufacturer-calibrated sensors (hereafter, “continuous fluorescence”) and collected continuously are often different from the precise Chl-a concentrations obtained from discrete, extracted samples. Moreover, underway fluorometers and manufacturer calibrations differ per cruise. Thus, post-calibration of the continuous fluorescence signals using discrete Chl-a measurements is essential to standardize and compare the high-resolution underway Chl-a data along cruise tracks. For six cruises aboard the R/V Endeavor between summer 2019 and summer 2021, 12 to 22 discrete samples were collected from the underway system to measure Chl-a concentrations. These discrete Chl-a concentrations were then compared, using simple linear regressions (Model I least square fit), to corresponding continuous fluorescence values recorded by the two independent fluorometers installed with the underway system. For each cruise a preferred fluorometer was identified based on the best fit of the linear regression between discrete Chl-a concentrations and continuous fluorescence values. The slope and the intercept of the linear regression were used to post-calibrate continuous fluorescence values into standardized and intercomparable Chl-a concentration. This data package includes a table for the underway discrete Chl-a values and a table for the 1-min post-calibrated continuous fluorescence values for the preferred underway fluorometer per cruise.more » « less
An official website of the United States government
